MuTec - JIEKES, inline moisture meter, solid flow meter, dust monitor, weight and tape level transmitter, rotary blade level meter,sinus pinch valves etc.

Current Location: Home > Products > Acting brand > MuTec

found:26 please select a view type

Continuous Inline Moisture Measuring SystemHUMY3000
Continuous Inline Moisture Measuring SystemHUMY3000 [MuTec]
The moisture in solids is an important parameter which strongly influences the quality of the product and can increase the economic efficiency of a production fundamentally. HUMY3000 is in many processes successfully in use, e.g. for sugar, tobacco, grain, malt, flour, coal, sand, wood shavings, dried food, fertilizer, powder, pigments and plastic granules.As installation places conveyor belts, screw conveyors, silos, funnels are particularly suitable. The inline moisture measurement is also possible in batch processes.Main Benefits:● No samples for the laboratory necessary● Saving of energy costs● Improvement on the product quality● Very short amortization time● High selective sensitiveness● High measuring speed● Precision better than 0.1% (depends on product)● Easy and economic installation●Fast and simple calibration●Optional ATEX-Version for zone 20 and zone 0 
Mass Flow Measurement for Bulk MaterialsMF3000
Mass Flow Measurement for Bulk MaterialsMF3000 [MuTec]
Our solid flow meter MF 3000 is designed for flow measurement in metallic pipes from a few kg / h to many t / h. The system is suitable for on- line measurements of powders, dusts, pellets, and granules from 1 nm up to 2 cm in pneumatic or free fall conditions.The measurement principle of the MF 3000 is based on the physical Doppler-Effect, whereas the sensor generates a uniform field in the microwave frequency range inside the pipe. These microwaves are being reflected by particles passing through the pipe. Calculation of frequency and amplitude changes allows for accurate determination of solid flow. Non- moving particles like dust accumulation are excluded from the calculation.The installation is simple and cost effective via a welded branch, through which the sensor is screwed flush to the inside of the pipe. The sensor is connected to a DIN-rail mounted transmitter with 4...20 mA, RS232 and RS485 output. The calibration is easy by using our MF– SMART software and a reference flow value.Main Benefits:● For pneumatic conveyors and free falling processes; ● For all solid materials from a few kg/h to many t/h; ● No armatures inside the pipe and inside flush fitting; ● Very fast and contactless measurement; ● Easy, quick and cost effective installation and start-up; ● Galvanic separated DIN-Rail Transmitter with RS232- and RS485-Interface; ● Robust stainless steel version, abrasion and maintenance free;● Limit value monitoring with alarm contact; ● Sensor-transmitter distance up to 2.000 m; ● Easy and quick calibration; ● Adjustable sensitivity; ● Optional: ATEX for Zone 20 and Zone 2; 
Microwave Barrier LevelCheck 510M LC500M
Microwave Barrier LevelCheck 510M LC500M [MuTec]
The LevelCheck 510M microwave barrier is used to monitor limit levels of solids in silos, containers, storage tanks, pipe systems, etc. Additional applications include: blockage reports, counting piece goods, or positioning objects. The systems are certified up to ATEX Zone 20 and optionally authorised up to a process pressure of 25 bar. The measurement process of the LevelCheck 510M is based on the newest microwave technology, whereby the transmitter sends out a microwave signal which is analysed by the opposite receiver. Material which builds up within this field attenuates its signal effect, and this is then converted into a switching procedure. The measurement is contactless. The sensitivity, signal attenuation and signal hysteresis of the microwave barrier can easily be set continuously and precisely using the bar graph display. This allows for a variable determination of the switching point or a switching process for different process parameters.Main Benefits:● Reliablemicrowave measuringprinciple● Self-monitoring with additional relay● For level monitoring● Adjustable sensitivity, damping, hysteresis and filter function● Adjustment via 2 key buttons and bargraph● Easy installation by compact form● Process connection with flange, thread, etc.
Dust Monitor for Detecting Filter Malfunctions FS700E01
Dust Monitor for Detecting Filter Malfunctions FS700E01 [MuTec]
The FlowSwitch 700E dust monitor is used to detect filter malfunctions caused by cracks or installation defects, for instance. The triboelectric measurement principle makes it possible to reliably detect dust penetration.Main Benefits:●  Maintenance free●  Adjustable sensitivity●  Adjustable switch●  Condition indication with LED●  Stainless steel housing●  Compact form●  Easy installation
High Speed SIL2-thermocouple TransmitterMTP 300i SIL
High Speed SIL2-thermocouple TransmitterMTP 300i SIL [MuTec]
Powerful Properties:2-wire temperature transmitter for DIN rails2 galvanic isolated TC-inputs with cold-junction compensationSignal pass-through time:     without Butterworth filter ≤ 3 ms      with Butterworth filter ≤ 38 msInstallation in zone 1 or 2 permissibleIntrinsic safety according to IEC/EN 60079-11Error indication according to NAMUR NE 43Green LED for Signal indicationEasy operation:Power supply via rail or terminalSimple assemblingCertified:SIL2 according to IEC/EN 61508:2010IECEx - Ex ib [ia Ga] IIC T4 GbATEX II 2 (1) G Ex ib[ia] IIC T4
Relay BoardREG242
Relay BoardREG242 [MuTec]
SHORT DESCRIPTION4-channel relay board for an operation with small currents and voltagesPin-compatible to MC73-481-R from TurckRelay activation also with AC voltage possibleSafe galvanic isolation of control and contact circuitFour relays with two changeover contacts eachForm of construction: 19“, 4TE, 3HEFURTHER VERSIONSREG 222:4-times relay board with two channel pairsREG 241:4-channel relay boardREG 243:4-channel relay board with activation with 230 VACREG 281:8-channel relay board with one N/O contact for each channelREG 282:8-channel relay board with one changeover contacts for each channel 
SIL2-Transmitter power supply MSK 200-E
SIL2-Transmitter power supply MSK 200-E [MuTec]
SHORT DESCRIPTION1-channel measuring transmitter supply unit in DuoTec-Failsafe Technology with self-monitoring for the supply of 2-wire transmittersCertified according to IEC 61508 SIL2Output: 0/4-20 mA, 1-5/0-10 VDC4 individually adjustable limit values(2 relays contact outputs, 2 transistor output)1 service alarmSafe galvanical separation between auxiliary energy, input and outputExecuted on Namur recommendation NE 21HART-protocol sockets at the frontRS 485-interface at the edge of the measuring devicePC-connection via MÜTEC interface cable at the frontConfiguration ON-LINE by MÜTEC-WINSMART softwareAuxiliary energy: 24VDC/ACForm of construction: 19“, 4TE, 3HEOPTION "IEXA"Input II (1) G Ex ia IIC, (zone 0) 
mV TransmitterMSK200 DV
mV TransmitterMSK200 DV [MuTec]
SHORT DESCRIPTIONRedundant mV-input with Butterworth filterTransmitter in DuoTec-Failsafe Technology with self-monitoring according to IEC 61508Executed on Namur recommendation NE 21Measuring range: 0…100 mV DCOutput: 0/4-20 mA, 0/2-10 V DC3 individually adjustable limit values (2 relays contact outputs,1 transistor output)1 collective alarm relay contactPC connection at the frontRS 485 Bus connection via mounting rail bus connectorConfiguration: ON-LINE by MÜTEC-WINSMART softwareGalvanically separated between auxiliary energy, input and output (3 Port separation)Test voltage 2.5kV AC, working voltage 800 V AC/DC by overvoltage category IIAuxiliary energy: 24V AC/DCForm of construction: DIN-Rail mounting, DIN EN 5002
Voltage Monitoring TransmitterMSK 200-DX
Voltage Monitoring TransmitterMSK 200-DX [MuTec]
SHORT DESCRIPTIONRedundant voltage input for up to 1000 VTransmitter in DuoTec-Failsafe Technology with self-monitoring according to IEC 61508Executed on Namur recommendation NE 21Measuring range: 0…+/- 250 V DCOutput: 0/4-20 mA, 0/2-10 V DC3 individually adjustable limit values (2 relays contact outputs,1 transistor output)1 collective alarm relay contactPC connection at the frontRS 485 Bus connection via mounting rail bus connectorConfiguration: ON-LINE by MÜTEC-WINSMART softwareGalvanically separated between auxiliary energy, input and output (3 Port separation)Test voltage 2.5kV AC, working voltage 800 V AC/DC by overvoltage category IIAuxiliary energy: 24V AC/DCForm of construction: DIN-Rail mounting, DIN EN 5002
Voltage Control SystemMSK 200-DP
Voltage Control SystemMSK 200-DP [MuTec]
SHORT DESCRIPTIONRedundant differential voltage inputs for up to 750 VTransmitter in DuoTec-Failsafe Technology with self-monitoring according to IEC 61508Executed on Namur recommendation NE 21Measuring range: 0…+/-250 V DCOutput: 0/4-20 mA, 0/2-10 V DC3 individually adjustable limit values (2 relays contact outputs,1 transistor output)1 collective alarm relay contactPC connection at the frontRS 485 Bus connection via mounting rail bus connectorConfiguration: ON-LINE by MÜTEC-WINSMART softwareGalvanically separated between auxiliary energy, input and output (3 Port separation)Test voltage 2.5kV AC, working voltage 800 V AC/DC by overvoltage category IIAuxiliary energy: 24V AC/DCForm of construction: DIN-Rail mounting, DIN EN 5002
SIL2-Transmitter power supply with 2 outputsMSK 200i-TV2
SIL2-Transmitter power supply with 2 outputsMSK 200i-TV2 [MuTec]
SHORT DESCRIPTION2-channel measuring transmitter supply unit in DuoTec-Failsafe Technology with self-monitoring for the supply of 2-wire transmitterCertified according to IEC 61508 SIL22 Outputs: 0/4-20 mA, 0/2-10 VDC4 individually adjustable limit values (2 relays contact outputs, 2 transistor outputs)1 service alarmFunction for rate of changeSafe galvanical separated between auxiliary energy, input and outputExecuted on Namur recommendation NE 21HART-protocol sockets at the frontRS 485 Bus connection via mounting rail bus connectorPC-connection via MÜTEC interface cable at the frontConfiguration ON-LINE by MÜTEC-WINSMART softwareAuxiliary energy: 24 VDC/ACForm of construction: DIN-Rail mounting, DIN EN 50022OPTION "IEXA"Input II (1) G Ex ia IIC, (zone 0)
SIL2-Transmitter power supplyMSK 200-TE
SIL2-Transmitter power supplyMSK 200-TE [MuTec]
SHORT DESCRIPTION1-channel measuring transmitter supply unit in DuoTec-Failsafe Technology with self-monitoring for the supply of 2-wire transmittersCertified according to IEC 61508 SIL2Output: 0/4-20 mA, 1-5/0-10 VDC3 individually adjustable limit values(2 relays contact outputs, 1 transistor output)1 service alarmSafe galvanical separation between auxiliary energy, input and outputExecuted on Namur recommendation NE 21HART-protocol sockets at the frontRS 485 bus connection via mounting rail bus connectorPC-connection via MÜTEC interface cable at the frontConfiguration ON-LINE by MÜTEC-WINSMART softwareAuxiliary energy: 24VDC/ACForm of construction: DIN-Rail mounting, DIN EN 50022OPTION "IEXA"Input II (1) G EEx ia IIC, (zone 0)
SIL2-Universal transmitterMTP 200-TE
SIL2-Universal transmitterMTP 200-TE [MuTec]
HORT DESCRIPTIONUniversal measuring transmitter in DuoTec-Failsafe Technology with self-monitoringCertified according to IEC 61508 SIL2Input: Resistor and Pt100 with 2-, 3- and 4-wire switch, all types of thermocouple, current, voltageOutput: 0/4-20 mA, 1-5/0-10 VDC3 individually adjustable limit values (2 relays contact outputs, 1 transistor output)1 service alarmSafe galvanical separation between auxiliary energy, input and outputExecuted on Namur recommendation NE 21RS 485 bus connection via mounting rail bus connectorPC-connection via MÜTEC interface cable at the frontConfiguration ON-LINE by MÜTEC-WINSMART softwareAuxiliary energy: 24VDC/ACForm of construction: DIN-Rail mounting, DIN EN 50022OPTION "IEXA"Input II (1) G Ex ia IIC, (zone 0)
Fuse CardSVM 24x
Fuse CardSVM 24x [MuTec]
SHORT DESCRIPTION4-channel fuse card for protection of four separated circuitsPin-compatible to MC83-4SI from TurckProtection of circuits realized by safety fuses in the frontCommon or separated inputs possibleMaximum load current up to 5AProtection up to 24 VDC / 5AError-LEDsForm of construction: 19“, 4TE, 3HEFURTHER VERSIONSSVM 22x:2-channel fuse card
Valve Control ModuleVST 240io
Valve Control ModuleVST 240io [MuTec]
SHORT DESCRIPTION4-channel valve control module for triggering of valve controls and to supply of intrinsically safe 2-wire transmittersPin-compatible to MC72-41Ex-T from Turck Intrinsically safe output circuits II (2) G Ex ib Gb IIC, (zone 1)Output voltage values adjustable: 3 fixed values, 1 freely adjustable valueGalvanic isolated output circuitsGalvanic isolated control input circuitsUndervoltage switch-off Auxiliary power 24 VDCForm of construction: 19“, 4TE, 3HE
Switching AmplifierINK 240i
Switching AmplifierINK 240i [MuTec]
SHORT DESCRIPTION4-channel  witching amplifier with four separated output circuitsCompatible to MC13-441Ex0-T from TurckIntrinsically safe input circuits II (1) G Ex ia Ga IIC, (zone 0)Maximum load current up to 200 mABreak und short circuit monitoring of control circuits with Error-notification at the frontGalvanic isolated output circuits (all sides)Output 4 can also be used as error alarm Auxiliary energy 24 VDCForm of construction: 19“, 4TE, 3HEFURTHER VERSIONSINK 250i:4-channel-switching amplifier with five separated output circuits
Continuous Inline Moisture Measuring SystemHUMY3000
Continuous Inline Moisture Measuring System
[HUMY3000]
Mass Flow Measurement for Bulk MaterialsMF3000
Mass Flow Measurement for Bulk Materials
[MF3000]
Microwave Barrier LevelCheck 510M LC500M
Microwave Barrier LevelCheck 510M
[LC500M]
Dust Monitor for Detecting Filter Malfunctions FS700E01
Dust Monitor for Detecting Filter Malfunctions
[FS700E01]
High Speed SIL2-thermocouple TransmitterMTP 300i SIL
High Speed SIL2-thermocouple Transmitter
[MTP 300i SIL]
Relay BoardREG242
Relay Board
[REG242]
SIL2-Transmitter power supply MSK 200-E
SIL2-Transmitter power supply
[MSK 200-E]
mV TransmitterMSK200 DV
mV Transmitter
[MSK200 DV]
Voltage Monitoring TransmitterMSK 200-DX
Voltage Monitoring Transmitter
[MSK 200-DX]
Voltage Control SystemMSK 200-DP
Voltage Control System
[MSK 200-DP]
SIL2-Transmitter power supply with 2 outputsMSK 200i-TV2
SIL2-Transmitter power supply with 2 outputs
[MSK 200i-TV2]
SIL2-Transmitter power supplyMSK 200-TE
SIL2-Transmitter power supply
[MSK 200-TE]
SIL2-Universal transmitterMTP 200-TE
SIL2-Universal transmitter
[MTP 200-TE]
Fuse CardSVM 24x
Fuse Card
[SVM 24x]
Valve Control ModuleVST 240io
Valve Control Module
[VST 240io]
Switching AmplifierINK 240i
Switching Amplifier
[INK 240i]
Total 26 items/16 items per page First Previous 1 2Next End

morePrint | Website Map | Jiekes·China 2024

Products Brand Classific Application News About us
MuTec
MOLLET
HENSE
BlueLevel
AgraTronix
Sintrol
PTL
Expert Knowledge
Technical Articles
Solution
Download
Video
Latest News
Events
Exhibition
Company Profile
Brand Meaning
Company Culture
Job Offers
Service Team

What can We do for you?

Please send E-mail to us
Please leave a message
china@jiekes.com
Please leave a message
If you want more informations, please leave a message.
Online message
Please call us
If you require anything , please dial 400 freephone to call us.
4006 911718



京ICP备10051444号-3