High Speed SIL2-thermocouple Transmitter - JIEKES, inline moisture meter, solid flow meter, dust monitor, weight and tape level transmitter, rotary blade level meter,sinus pinch valves etc.

Current Location: Home > 产品 > Analytical instrumen > High Speed SIL2-thermocouple Transmitter

Name:High Speed SIL2-thermocouple Transmitter
Type:MTP 300i SIL
Introduction:

Powerful Properties:
2-wire temperature transmitter for DIN rails
2 galvanic isolated TC-inputs with cold-junction compensation
Signal pass-through time:
     without Butterworth filter ≤ 3 ms      with Butterworth filter ≤ 38 ms
Installation in zone 1 or 2 permissible
Intrinsic safety according to IEC/EN 60079-11
Error indication according to NAMUR NE 43
Green LED for Signal indication

Easy operation:
Power supply via rail or terminal
Simple assembling

Certified:
SIL2 according to IEC/EN 61508:2010
IECEx - Ex ib [ia Ga] IIC T4 Gb
ATEX II 2 (1) G Ex ib[ia] IIC T4

The 2-wire temperature transmitter MTP300i- SIL-K has been designed for the operation of intrinsically safe thermocouple circuits installed in the Ex area. Each TC-input terminal is equipped with a Pt100 sensor for the cold- junction compensation. The TC transmitter must be intrinsically safe supplied by a repeater power supply or ZENER barrier. Both thermocouple signals are galvanic isolated. The devices can be installed in zone 1 or 2 with the “n” (IEC/EN 60079-15) protection type.

Certificates
ATEX certificate BVS 08 ATEX E 082 X + 4. Supplement
II 2 (1) G Ex ib[ia] IIC T4
IECEx certificate BVS 14.0073X
Ex ib [ia Ga] IIC T4 Gb
Functional Safety (SIL)
SIL 2 according to EN 61508
Safety data according to ATEX for intrinsically safe circuits
Power supply - Ex ib IIC (terminals 1 and 4)
Ui Voltage: 28 V DC
Ii Current: 95 mA
Pi Power: 655 mW
Ci Effective inner capacity 26 nF
Li Effective inner inductivity negliable
Thermocouple inputs - Ex ia IIC and Ex ib IIC (terminals 5 and 8, 9 and 12)
Uo Voltage 1 V DC
Io Current 1.8 mA
Po Power 0.5 mW
Co Permissible outer capacity  10pF
Lo Permissible outer inductivity   100mH
Input signal (terminals 5 and 8, 9 and 12)
Thermocouple: NiCr-Ni 0 ... 400°C
Cold-junction compensation: -10 to +70°C
Output signal (terminals 1 and 4)
Io Current: 4 …20 mA
Io Maximum current: < 24 mA
Io Behavior by defect (NE 43): 3.6 mA
Status indicator:
Green LED: luminosity corresponds to 4 ... 20 mA
Behavior by defect: dark
Snap in TBUS-Connector àturn housingà device installed


 

 

General data
Signal pass-through time
Without 50/60 Hz Butterworth filter: 3 ms
With 50/60 Hz Butterworth filter: 38 ms
Transmission error
Typical: <0.1 % (of final value)
Maximum:<0.2% (of final value)
Temperature coefficient
Typical: <0.05% /10 K
Maximum:<0.1% /10 K
Cold-junction compensation error
 Temperature range  <0.5 °C
0°C to +50°C
Temperature range  <1.0 °C
-10°C to +70°C
 Linearization error
Typical: <0.1 °C Maximum: <0.2 °C
Electric Isolation
Tested according norms & rules EN 60079-11:
Electromagnetic compatibility
Tested according norms & rules EN 61326-3-2
Current loop supply
Voltage range:   12.5 … 28 V
Current range: >3.5 … <24 mA
Power dissipation
Minimum  50 mW
(12.5 V x 4 mA):
Maximum 560 mW
(28 V x 20 mA):
Ambient temperature
Operation
: -10 to +70 °C
Storage/transport: -20 to +80 °C
Humidity
Permissible operation humidity (no condensation) -10 ... 95 %
Housing
Material:
 Polyamide
Color: light grey
Degree of protection IP20
Width x length x height (with  22.5 x 115 x 108 mm connection terminal blocks)
Inflammability dass VO
according to UL 94
Housing type for mounting 35 mm DIN rails
Weight with terminal blocks   approx. 200 g

Connection data
Solid:
          0.2 / 2.5mm2
 (minimum/maximum)
Stranded:  0.2 / 2.5mm2
(minimum/maximum)
 AWG:        24/14kcmil
 (minimum/maximum)
Stripping length 7 mm
Connection method Plugable screw connection
Tightening torque 0.5 … 0.6 Nm
Installation
Safe area:
 Install the device in a clean and dry environment.
Ex area (zone 1 or 2): Install the device in a suitable housing with a minimum of IP54 degree of protection.

 

The 2-wire temperature transmitter MTP300i-SIL-K has been designed for the operation of intrinsically safe thermocouple circuits installed in the Ex area.The TC input is equipped with a Pt100 sensor for the cold-junction compensation.The TC transmitter must be intrinsically safe supplied by a repeater power supply or ZENER barrier. The thermocouple signal is galvanic isolated. The device can be installed in zone 1 or 2 with the “n” (IEC/EN 60079-15) protection type.

No Download

morePrint | Website Map | Jiekes·China 2024

Products Brand Classific Application News About us
MuTec
MOLLET
HENSE
BlueLevel
AgraTronix
Sintrol
PTL
Expert Knowledge
Technical Articles
Solution
Download
Video
Latest News
Events
Exhibition
Company Profile
Brand Meaning
Company Culture
Job Offers
Service Team

What can We do for you?

Please send E-mail to us
Please leave a message
china@jiekes.com
Please leave a message
If you want more informations, please leave a message.
Online message
Please call us
If you require anything , please dial 400 freephone to call us.
4006 911718



京ICP备10051444号-3